ID Made Easy
Research Get in Touch Shop
LITETemperature Monitoring · USB Plug-and-Play

AnyCage Lite

Continuous, non-invasive temperature monitoring for single-cage and small-cohort studies — at a price that makes it easy to start.

TemperatureActivity
AnyCage Lite temperature monitoring reader mounted on a mouse home cage
Illustration of a mouse in a home cage with the AnyCage Lite antenna mounted above
Product Overview

Temperature monitoring tied to a specific animal, right inside the home cage

AnyCage Lite uses the UID UCT-2112 temperature-sensing microchip — the same implantable transponder used across UID's lab animal identification line. Each chip supports ±0.1°C accuracy across 30–46°C, and every reading is tied to a specific animal's ID. Sensor plates can show activity in a cage; AnyCage Lite ties temperature back to the animal.

The system is plug-and-play USB, designed for labs running single-cage studies or small cohorts. Each reader sits at the cage. No dedicated controller. No server. Plug a reader into a lab workstation, open the Data Collector software, and you can start logging continuous temperature data the same day.

AnyCage Lite supports up to eight readers per PC, so you can start with one cage and grow into a larger cohort as the project does. Each additional reader is $300, so expansion stays incremental and predictable.

Key Capabilities

Built for simplicity. Designed for science.

Six reasons AnyCage Lite fits single-cage and small-cohort temperature studies.

  • Per-animal identity

    Every reading is attributed to a specific animal — not just a cage or a sensor zone. Lineage, group housing, and individual records all stay clean as animals move.

  • Plug-and-play USB

    No dedicated controller. No server. Connect a reader to a lab PC over USB, open the Data Collector software, and start logging the same day the kit arrives.

  • Flexible antenna options

    Choose a 3″ round or 2″×5″ rectangular antenna; mount magnetically or with the included clip to fit standard cage tops and rack configurations.

  • Scales up to 8 readers

    Grow from a single cage to eight readers on one workstation. Add readers at $300 each as your study design expands — same software, no upgrade.

  • ±0.1°C accuracy

    UID UCT-2112 temperature-sensing microchips support ±0.1°C temperature accuracy across 30–46°C, based on UID validation testing against rectal probe reference measurements, with every read tied to an individual animal ID.

  • Non-invasive & IACUC documentation support

    Continuous monitoring without daily handling supports Refinement under the 3Rs. Passive transponders and automated logging reduce handling events and help keep welfare documentation tied to the individual animal.

Pricing & Kits

Straightforward pricing. Nothing hidden.

What you need to start monitoring on day one, with room to grow as your study does.

AnyCage Lite 4-Cage Reader Kit

$1,995
One-time purchase — software included

Supports up to eight readers per workstation — expand by adding components individually as your study grows.

Kit includes
  • 4× AnyCage Lite Readers with 3″ Round Antennas
  • 4× (2″×5″) Rectangular Antennas
  • USB 4-Port Hub
  • Pack of 24 UID temperature transponders (sterile cannula)
  • Pistol Grip Microchip Injector
  • Data Collector Software for AnyCage Lite
Let's Get Started

Additional Components

Add readers and accessories as you go
Individual items
  • Additional AnyCage Lite Reader $300 each
  • Replacement Round Antenna $50
  • Replacement Rectangular Antenna $50
  • Magnetic Mounts (pack of 20) $45
  • 4-Port Cradle $150
  • Antenna Cable $19
View Full Shop
Product Comparison

Pick the right system for your study

All three platforms share the same UID UCT-2112 microchip ecosystem. Your choice comes down to study size, data needs, and infrastructure.

Feature Current product: AnyCage Lite Individual cages · Small studies AnyCage+ Rack-scale · Large cohorts Mouse Matrix Activity and physiological data
Monitors Temperature Temperature Temperature + Activity + Location
Ideal for Single cages, small studies Rack-scale, large cohorts Detailed activity and physiological data
Scalability Up to 8 cages Up to 96 cages per system Up to 48 per system
Animals tracked Individual or group-housed up to 5/cage Individual or group-housed up to 5/cage Individual or group-housed up to 5/cage
Monitoring rate Continuous (if connected to PC) Continuous Continuous w/ ea. zone scanned every 100–250 ms
Mount Magnetic or clip mount Magnetic or clip mount Plate under cage
Connectivity USB + PC Controller, Hubs, Readers Controller, PoE switch, PC
Temp accuracy ±0.1°C (30–46°C) ±0.1°C (30–46°C) ±0.1°C (30–46°C)
Microchip UID UCT-2112 UID UCT-2112 UID UCT-2112
Software Data Collector VivoTraq Mouse Matrix
Get Started

Start monitoring in a single afternoon.

Plug in, open the software, and log your first temperature readings the same day the kit arrives. No installation appointments. No server configuration. No waiting.